Administrator
|
The “M” applies to the Mechanical Pump and the integrated protocol with the
Tagging. With the Digital Pump, there will be about another 10 different device
Codes that will also be going via the MID to the Pumps. I would like to make sure
we cater for this understanding now and but focus on the Mech type for now. I
believe it will be simpler if the Digital was done on the Wrapped protocol as
this would enable the Digital Pump comms and the Tagging to be one process.
Download Command 0x18 –
Tech Config: Memory Locations per device setting
|
Field Name
|
Data
|
example
|
DeviceCode, Index
|
GRPS Mode
|
G,0x04539
|
DeviceCode, Index
|
Mech Pump&Tag
|
M,0x00CDFD
|
DeviceCode, Index
|
UHF Tagging
|
U,0x000CF44
|
DeviceCode, Index
|
GPS
|
S,0x00654C
|
DeviceCode, Index
|
Printer
|
Q,0x0034DC
|
DeviceCode, Index
|
UHF Tagging
|
A,0x005434
|
|
|
|
Below a sample of the comms from the Web to the M/C
|
STX
[1] Hex
|
SiteID[3]
Hex
|
Packet Type[2] Hex
|
Payload length [1]
Hex
|
Payload
|
CRC [1]
Hex
|
ETX
[1]
Hex
|
0x32
|
0x04FD00
|
0x02
|
0xnn
|
G,0x04539| M,0x00CDFD etc
|
XX
|
0x33
|
|