Download Command 0x1b – Tech Config: Pump Type Transaction Control Parameters

classic Classic list List threaded Threaded
1 message Options
Reply | Threaded
Open this post in threaded view
|

Download Command 0x1b – Tech Config: Pump Type Transaction Control Parameters

'Neal Singh
Administrator
This is requirement for the Pump as there may be formatting issues with the data coming from the Pump that would need to be adjusted so as to appear as it does on the Pump display (Legal requirement)  
It also controls adjustments to the Preauth Command
Not sure how the uC will find this data, maybe the Download Command Code.. or it get added to the other data regarding the devices.


Download Command 0x1b – Tech Config:  Pump Type Transaction Control Parameters

Field Name

Data e.g

Description

PumpCode

0x01 (TokheimWWC)

Digital Pump Code

SalesValueLeft

0

Move Decimal Pt left

SalesValueRight

1

Move Decimal Pt Right 1= 1 shift to the left

SalesLitresLeft

0

Move Decimal Pt left

SalesLitresRight

0

Move Decimal Pt Right

Preauthx10

1

The Preauth Value x 10 (2= 20)

Preauth/10

0

The Preauth Value / 10

PriceSetx10

0

If the price set need manipulation

PriceSet/10

0

 

PumpCode

0x02 (Tokheim33)

Digital Pump Code

SalesValueLeft

0

Move Decimal Pt left

SalesValueRight

1

Move Decimal Pt Right 1= 1 shift to the left

SalesLitresLeft

0

Move Decimal Pt left

SalesLitresRight

0

Move Decimal Pt Right

Preauthx10

1

The Preauth Value x 10 (2= 20)

Preauth/10

0

The Preauth Value / 10

PriceSetx10

0

If the price set need manipulation

PriceSet/10

0

 

Below a sample of the comms from the Web to the M/C

STX

[1] Hex

SiteID[3]

Hex

Packet Type[2] Hex

Payload length [1]

Hex

Payload

 

CRC [1]

Hex

ETX

 [1]

Hex

0x32

0x04FD00

0x04

0xnn

0x01|..etc

XX

0x33